AC output Load
|
VMI-D
3000W
|
VMI-D
4000W
|
VMI-D
5000W
|
Nominal AC voltage
Optional 220V/120V
|
220V/200-240V
120V/105V-132V
|
220V/200-240V
120V/105V-132V
|
220V/200-240V
120V/105V-132V
|
Nominal AC frequency
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
Continuous AC power for 3 hours 25℃
|
2700W
|
3600W
|
4500W
|
Continuous AC power 25℃
|
2400W
|
3200W
|
4000W
|
Nominal AC current/ Max.AC current(peak)
|
10.91A/32.73A 1ms
20.0A/60.0A 1ms
|
14.55A/43.63A 1ms
26.66A/80.0A 1ms
|
18.19A/54.55A 1ms
33.33A/99.99A 1ms
|
THD output voltage
|
≤3%
|
≤3%
|
≤3%
|
Power Factor
|
0.8
|
0.8
|
0.8
|
AC input(generator or grid)
|
|
|
|
AC input voltage/range
|
220V/165-270V
120V/105V-132V
|
220V/165-270V
120V/105V-132V
|
220V/165-270V
120V/105V-132V
|
AC input frequency
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
Battery DC input
|
|
|
|
Battery voltage/range
Optional
|
12V/10-16V
24V/20-32V
48V/40-64V
|
24V/20-32V
48V/40-64V
|
24V/20-32V
48V/40-64V
|
Max.battery charging current/continuous charging current at 25℃
|
30A/10-30A/50A
|
30A/10-30A/50A
|
30A/10-30A/50
|
Battery type/Battery Capacity
|
Lead acid 100-1000Ah
|
Lead acid 100-1000Ah
|
Lead acid 100-1000Ah
|
Charge control mode
|
3 stage
|
3 stage
|
3 stage
|
Efficiency/Self-consumption
|
|
|
|
Max.efficiency
|
>85%
|
>85%
|
>85%
|
Self-consumption with no load
|
30W
|
30W
|
30W
|
Self-consumption with no load /standby/for LCD type only
|
5W
|
5W
|
6W
|
Full intellective protection
|
Over voltage/over charge/AC short circuit/overload/battery discharge voltage/battery over voltage/overtemperature/over current/overheat protection/ dc polarity label
|
Transfer time
|
≤ 4ms
|
Dimenstion(L×W×H)
|
540×250×196mm
|
540×250×196 mm
|
540×250×196 mm
|
Net Weight
|
29
|
32
|
36
|
Operating temperature range
|
-20℃ ~ 45℃
|
-20℃ ~ 40℃
|
-20℃ ~ 45℃
|
Degree of protection according to IEC60529
|
IP20
|
IP20
|
IP20
|
Noise emission typical
|
≤30dB (1M)
|
≤30dB (1M)
|
≤30dB (1M)
|
Permissible value for relative humidity
|
0% ~ 95%
|
0% ~ 95%
|
0% ~ 95%
|
Accessories
|
|
|
|
DC terminal
|
Anderson connector
|
Anderson connector
|
Anderson connector
|
AC terminal
|
Europe terminal
|
Europe terminal
|
Europe terminal
|
Warranty
|
2year
|
2year
|
2year
|
Certificate
|
CE/ISO9001
|
CE/ISO9001
|
CE/ISO9001
|
Instruction Manual
|
yes
|
yes
|
yes
|
Optional Function
|
|
|
|
Battery Cable
|
Optional
|
Optional
|
Optional
|
Interface USB/RS232
|
Optional
|
Optional
|
Optional
|
SNMP Card
|
Optional
|
Optional
|
Optional
|
Software CD
|
Optional
|
Optional
|
Optional
|
Internet monitor
|
Optional
|
Optional
|
Optional
|
Remoted control
|
Optional
|
Optional
|
Optional
|
DC reverse polarity protection
|
Optional
|
Optional
|
Optional
|
Automatically restart after cut off
|
Optional
|
Optional
|
Optional
|
Split phase 220V/110V+-5%:output
|
Optional
|
Optional
|
Optional
|
Alarm at inverter mode/silence
|
Optional
|
Optional
|
Optional
|
LCD Display
|
Optional
|
Optional
|
Optional
|