ProductCharacteristic
High Efficiency/Energy Saving
Low self-Consumption below 1.2A.It canreach zero at energy saving mode.
Make sure the load capacity is above200W.or the inverter can not be restarted automatically
Leading energy saving technology
With the AVR function.AC voltage fluctuatedis within +-5%
Pure sine wave
Extreme overload capacity and super loadcapacity
WorkingAppliance:Air-conditioners.refrigerators.water pumps.TV.Light.fans and other householdappliances and office appliances etc.
Durable. LF transformer technologydesign.it is suitable for the poor working conditions or where the grid poweris not stable
LED display LCD display optional
DC reverse polarity protection
PerformanceCharacteristic
CPU Technology control
Big Charging current. up to 70Amp.
Intelligent LED/LCD display:Grid powe.battery.ACoutput.Fault.Saving.Low voltage.Charging.
Charging curren.Battery capacity.
Intelligent battery management for maximumbattery life
Automatically switch between the grid andinverter mode
Transfer time is below 4 ms if the gridpower are cutted off
220V/110V AC 50/60Hz is optional
It can work with the generator
Intelligent fan control mode.The fan workat Temperature
≥30℃.the inverter will protect by itselfat temperature
≥100℃
Technical data(LCD)
Input/Output voltage
|
Output Power
|
Battery Voltage
|
Charge current
|
Input Frequency
|
Charge current setting
|
Language Version:Chinese/English/French/Russian
|
Charging voltage setting
|
Battery Capacity setting
|
Battery type
setting
|
Solar Prior
Grid prior setting
|
Energy saving
|
CommunicationData
Current
|
Rated power of load
|
Input/output voltage
|
Frequency
|
Battery capacity
|
Temperature
|
Remote control operation
|
Record of history data
|
TechnicalData
POWER SUN
AC output Load
|
VMI-D
3000W
|
VMI-D
4000W
|
VMI-D
5000W
|
Nominal AC voltage
Optional 220V/120V
|
220V/200-240V
120V/105V-132V
|
220V/200-240V
120V/105V-132V
|
220V/200-240V
120V/105V-132V
|
Nominal AC frequency
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
Continuous AC power for 3 hours 25℃
|
2700W
|
3600W
|
4500W
|
Continuous AC power 25℃
|
2400W
|
3200W
|
4000W
|
Nominal AC current/ Max.AC current(peak)
|
10.91A/32.73A 1ms
20.0A/60.0A 1ms
|
14.55A/43.63A 1ms
26.66A/80.0A 1ms
|
18.19A/54.55A 1ms
33.33A/99.99A 1ms
|
THD output voltage
|
≤3%
|
≤3%
|
≤3%
|
Power Factor
|
0.8
|
0.8
|
0.8
|
AC input(generator or grid)
|
|
|
|
AC input voltage/range
|
220V/165-270V
120V/105V-132V
|
220V/165-270V
120V/105V-132V
|
220V/165-270V
120V/105V-132V
|
AC input frequency
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
Battery DC input
|
|
|
|
Battery voltage/range
Optional
|
12V/10-16V
24V/20-32V
48V/40-64V
|
24V/20-32V
48V/40-64V
|
24V/20-32V
48V/40-64V
|
Max.battery charging current/continuous charging current at 25℃
|
30A/10-30A/50A
|
30A/10-30A/50A
|
30A/10-30A/50
|
Battery type/Battery Capacity
|
Lead acid 100-1000Ah
|
Lead acid 100-1000Ah
|
Lead acid 100-1000Ah
|
Charge control mode
|
3 stage
|
3 stage
|
3 stage
|
Efficiency/Self-consumption
|
|
|
|
Max.efficiency
|
>85%
|
>85%
|
>85%
|
Self-consumption with no load
|
30W
|
30W
|
30W
|
Self-consumption with no load /standby/for LCD type only
|
5W
|
5W
|
6W
|
Full intellective protection
|
Over voltage/over charge/AC short circuit/overload/battery discharge voltage/battery over voltage/overtemperature/over current/overheat protection/ dc polarity label
|
Transfer time
|
≤
4ms
|
Dimenstion(L×W×H)
|
540×250×196
|
540×250×196
|
540×250×196
|
Net Weight(kgs)
|
29
|
32
|
36
|
Operating temperature range
|
-20℃
~ 45℃
|
-20℃
~ 40℃
|
-20℃
~ 45℃
|
Degree of protection according to IEC60529
|
IP20
|
IP20
|
IP20
|
Noise emission typical
|
≤30dB (1M)
|
≤30dB (1M)
|
≤30dB (1M)
|
Permissible value for relative humidity
|
0% ~ 95%
|
0% ~ 95%
|
0% ~ 95%
|
Accessories
|
|
|
|
DC terminal
|
Anderson connector
|
Anderson connector
|
Anderson connector
|
AC terminal
|
Europe terminal
|
Europe terminal
|
Europe terminal
|
Warranty
|
2year
|
2year
|
2year
|
Certificate
|
CE/ISO9001
|
CE/ISO9001
|
CE/ISO9001
|
Instruction Manual
|
yes
|
yes
|
yes
|
Optional Function
|
|
|
|
Battery Cable
|
Optional
|
Optional
|
Optional
|
Interface USB/RS232
|
Optional
|
Optional
|
Optional
|
SNMP Card
|
Optional
|
Optional
|
Optional
|
Software CD
|
Optional
|
Optional
|
Optional
|
Internet monitor
|
Optional
|
Optional
|
Optional
|
Remoted control
|
Optional
|
Optional
|
Optional
|
DC reverse polarity protection
|
Optional
|
Optional
|
Optional
|
Automatically restart after cut off
|
Optional
|
Optional
|
Optional
|
Split phase 220V/110V+-5%:output
|
Optional
|
Optional
|
Optional
|
Alarm at inverter mode/silence
|
Optional
|
Optional
|
Optional
|
LCD Display
|
Optional
|
Optional
|
Optional
|
|
|
|
|
|
|
|
|
Due to continuous innovation.research andproduct improvement.the specifications in this product information sheet aresubject ot change without prior notice.the specifications may deviate slightlyand are not guaranteed.
The data do not refer to single module ofcontract and they are not part of the offer.they only serve for comparison todifferent module types
|